Specifying switchgear correctly starts with speaking the same language as the datasheet. This glossary runs through the core terminology you'll encounter across circuit breakers, contactors, relays and distribution components — including the din rail power relay, a term that comes up often but is rarely defined clearly. Bookmark it as a quick reference the next time a datasheet, RFQ or drawing uses a term you want to double-check before ordering.

Need help specifying switchgear for your site?

Talk to Our Expert Team

Core Terms A-Z

Term

Definition

Typical Standard

MCB (Miniature Circuit Breaker)

Automatically-resettable overcurrent protection for final circuits, sized up to around 125A

BS EN 60898-1 / IEC 60947-2

MCCB (Moulded Case Circuit Breaker)

Higher-current breaker with adjustable trip settings, used for distribution boards and larger loads

IEC 60947-2

ACB (Air Circuit Breaker)

Large-frame breaker used at main incomer and busbar level, often with electronic trip units

IEC 60947-2

RCD / RCCB / RCBO

Devices that detect current leaking to earth and disconnect the circuit to protect people from shock

BS EN 61008 (RCCB) / BS EN 61009 (RCBO)

Contactor

An electrically-operated switch for repeatedly making and breaking a power circuit, typically motor loads

IEC 60947-4-1 / UL 489

Thermal Overload Relay

A device that trips a motor circuit on sustained overload current, protecting the motor from overheating

IEC 60947-4-1

Switch Disconnector

A manually-operated device for isolating a circuit for maintenance, not intended for fault interruption

IEC 60947-3

Auxiliary Contact Block

An add-on module providing extra signalling contacts on a contactor or breaker

Tested with parent device (IEC 60947 series)

Busbar Distribution System

Rigid conductor system distributing power along a run, with tap-off points for individual circuits

IEC 61439

Din Rail Power Relay

A general-purpose electromechanical or solid-state relay mounted on standard DIN rail, used to switch control or small power loads independently of a motor contactor

UL 508 / IEC 60947-5-1

Motor Protection Circuit Breaker (MPCB)

A breaker combining short-circuit and adjustable overload protection sized specifically for motor starting current

IEC 60947-2

ACB (Air Circuit Breaker)

Large-frame breaker typically used at main incomer or busbar level, often with an electronic trip unit and higher breaking capacity than an MCCB

IEC 60947-2

RCCB

Standalone device that detects earth leakage current and disconnects the circuit, with no overload protection function of its own

BS EN 61008

RCBO

Combines RCD earth-leakage detection with MCB-style overcurrent protection in a single device

BS EN 61009

Isolator / Switch Disconnector

Manually-operated device for isolating a circuit for maintenance; not rated to interrupt fault current

IEC 60947-3

Contact Configuration (NO/NC)

Describes whether a contact is Normally Open or Normally Closed in its unoperated state, used on auxiliary contacts and relays

—

Coil Voltage

The voltage required to energise a contactor or relay coil (e.g. 24V dc, 230V ac) — must match the control circuit supply

—

DIN Rail

Standard 35mm metal rail used to mount circuit breakers, relays and terminals inside a distribution board or enclosure

EN 60715

Prospective Fault Current (PFC)

The maximum current that could flow at a point in the installation under fault conditions, used to check a breaker's breaking capacity is adequate

BS 7671

Discrimination / Selectivity

Design principle ensuring only the breaker closest to a fault trips, leaving upstream circuits energised

IEC 60947-2

Enclosure / IP Rating

A code (e.g. IP54, IP65) describing an enclosure's protection against dust ingress and water ingress

IEC 60529

Overload Protection

Protection against sustained excess current below short-circuit level, typically provided by a thermal overload relay or MCCB trip unit

IEC 60947-4-1

Short-Circuit Protection

Protection against a sudden, very high fault current, provided by the magnetic or instantaneous trip element of a breaker

IEC 60947-2

Cross-Reference

The process of matching a discontinued or obsolete part number to a current equivalent from the same or a different manufacturer

—

Related Standards Terms

Breaking capacity — the maximum fault current a breaker can safely interrupt without damage, usually expressed in kA. Trip curve (B/C/D) — defines how quickly an MCB trips relative to its rated current, matched to the type of load it protects. IP rating — describes the level of protection an enclosure provides against dust and water ingress. Pole count — the number of phases/conductors a device switches (1P, 2P, 3P, 4P). IEC 60947 — the international standard family covering low-voltage switchgear and controlgear, including circuit breakers (Part 2), switches and disconnectors (Part 3), and contactors and motor starters (Part 4-1). BS EN 60898 — the British/European standard for MCBs used in household and similar installations, closely related to but distinct from the industrial IEC 60947-2 standard. CE / UKCA marking — manufacturer declarations of conformity confirming a device meets the applicable EU or UK regulations for supply into that market.

Why Terminology Matters When Specifying

Getting the terminology right isn't academic — it directly affects what you order. Confusing an MCCB with an MCB, or an RCCB with an RCBO, can result in the wrong device being quoted, ordered, or installed. When raising an RFQ, use the correct term and cite the relevant standard where possible; it significantly reduces back-and-forth with your supplier and the risk of the wrong part arriving on site.

This matters just as much when cross-referencing an obsolete part as it does on a new specification. A part number alone doesn't tell a supplier whether you need an MCB, an RCBO, or a straightforward din rail power relay replacement — the functional term does, and it's the fastest way to get an accurate quote rather than a guess based on a photo of a nameplate. It's worth keeping a short glossary like this one alongside your panel drawings so anyone raising a purchase order — not just the original design engineer — is working from the same definitions.

Related Categories

Category

Description

Link

Miniature Circuit Breakers

MCBs across current ratings and trip curves

View Category

Contactor Relays

Contactors and control relays across brands

View Category

Thermal Overload Relays

Overload protection sized to motor F.L.C.

View Category

Motor Protection Circuit Breakers

MPCBs sized specifically for motor starting current

View Category

Frequently Asked Questions

What is a din rail power relay used for?

A DIN rail power relay switches a control or auxiliary load independently of the main motor contactor — commonly used for interlocking, signalling, or switching loads too small to warrant a full contactor. Typical applications include switching a heater, fan, or small pump directly from a PLC output, or providing electrical isolation between a low-voltage control signal and a mains-voltage load.

How do I choose between Allen-Bradley and ABB din rail power relays?

Match coil voltage, contact configuration and switching current to your control circuit design; both brands offer comparable ranges, so compatibility with existing panel equipment often decides the choice. Where the relay is replacing a failed unit on an existing board, matching the footprint and terminal layout as well as the electrical rating avoids reworking the wiring loom.

What standards apply to din rail power relays (UL 489)?

General-purpose power relays are typically tested to UL 508 or IEC 60947-5-1; UL 489 applies specifically to moulded-case circuit breakers rather than relays.

Can ZF Corporation source obsolete or discontinued din rail power relays?

Yes — we regularly cross-reference discontinued relay part numbers to current equivalents for panel repairs and upgrades, including where the original manufacturer no longer produces that exact coil voltage or contact configuration and a close equivalent needs sign-off from your engineering team first.

What is the typical lead time for a din rail power relay in the UK?

Common configurations are typically available from stock; less common coil voltages or obsolete cross-references may carry a short lead time.

Conclusion

Circuit breaker and switchgear terminology isn't difficult once the core terms are defined clearly — the key distinctions to remember are MCB vs MCCB vs ACB (scale), RCD/RCCB vs RCBO (what's combined), and contactor vs relay (load switched). Add din rail power relay vs contactor to that list too: a relay switches control and small power loads, while a contactor is built specifically for repeated motor switching duty. Bookmark this glossary for the next time a datasheet, drawing or RFQ uses a term you're not 100% sure of, and send it to a colleague who's newer to specifying switchgear.

Want to browse the full range referenced in this glossary?

Browse Our Product Range

DISCLAIMER: Z&F Corporation is not affiliated with, authorized by, endorsed by, or acting as an official representative of any manufacturer, brand, or trademark owner referenced on this website. All product names, trademarks, brand names, logos, and manufacturer references are the property of their respective owners and are used solely for identification, reference, and compatibility purposes.

#din rail power relay uk supplier#din rail power relay price uk#buy din rail power relay online#din rail power relay specification#din rail power relay ul 489#din rail power relay installation guide#din rail power relay cross reference#obsolete din rail power relay replacement#din rail power relay chart uk

Discussion

No comments yet. Be the first!

Leave a Comment

Your email won't be published. Comments are reviewed before appearing.