Electrical Controls

Product Category

Electrical Controls

1557 Products Found

Independent Supplier Notice — Z & F Corporation Ltd is not affiliated with, authorized by, endorsed by, or acting as an official representative of any manufacturer, brand, or trademark owner referenced on this website. All product names, trademarks, brand names, logos, and manufacturer references are the property of their respective owners and are used solely for identification, reference, and compatibility purposes.

Genuine OEM Guaranteed
No grey-market or counterfeit stock
Fast & Reliable Delivery
24-48hr dispatch on available items
Complete Documentation
Certificates & calibration records
Full Catalogue

All Electrical Controls Products

Showing 24 of 1557 products

General Electric 3300/35-11-01-01-00-00 - TEMPERATURE MONITOR 6CHANNEL 0-100DEG C 4-20MA
General Electric

General Electric 3300/35-11-01-01-00-00 - TEMPERATURE MONITOR 6CHANNEL 0-100DEG C 4-20MA

View Details
General Electric 3300/36-02-02-01-00-00 - DUAL TEMPERATURE MONITOR 0-300DEG/F
General Electric

General Electric 3300/36-02-02-01-00-00 - DUAL TEMPERATURE MONITOR 0-300DEG/F

View Details
General Electric 3300/35-03-02-02-00-00 - DISCONTINUED BY MANUFACTURER, SIX CHANNEL TEMPERATURE 4-20MA
General Electric

General Electric 3300/35-03-02-02-00-00 - DISCONTINUED BY MANUFACTURER, SIX CHANNEL TEMPERATURE 4-20MA

View Details
General Electric 3300/20-01-01-02-00-00 - DISCONTINUED BY MANUFACTURER, DUAL THRUST MONITOR RANGE, 25-0-25MILS
General Electric

General Electric 3300/20-01-01-02-00-00 - DISCONTINUED BY MANUFACTURER, DUAL THRUST MONITOR RANGE, 25-0-25MILS

View Details
General Electric 3300/25-01-12-12-00-00-01-00 - DUAL ACCELEROMETER MONITOR
General Electric

General Electric 3300/25-01-12-12-00-00-01-00 - DUAL ACCELEROMETER MONITOR

View Details
General Electric 3300/20-01-01-01-00-00 - DUAL THRUST MONITOR 25-0-25MILS
General Electric

General Electric 3300/20-01-01-01-00-00 - DUAL THRUST MONITOR 25-0-25MILS

View Details
General Electric 3300/16-14-01-00-00-00-00 - DISCONTINUED BY MANUFACTURER, DUAL VIBRATION MONITOR, MEASURES 2 INDEPENDENT CHANNELS, MEASURES RADIAL VIBRATION AND AVE
General Electric

General Electric 3300/16-14-01-00-00-00-00 - DISCONTINUED BY MANUFACTURER, DUAL VIBRATION MONITOR, MEASURES 2 INDEPENDENT CHANNELS, MEASURES RADIAL VIBRATION AND AVE

View Details
General Electric 3300/16-14-01-01-00-00-00 - DISCONTINUED BY MANUFACTURER, VIBRATION MONITOR, TWO CHANNEL, 0-400 MICRO-MILS PEAK-TO-PEAK FULL-SCALE RANGE, 3300(8 MM)
General Electric

General Electric 3300/16-14-01-01-00-00-00 - DISCONTINUED BY MANUFACTURER, VIBRATION MONITOR, TWO CHANNEL, 0-400 MICRO-MILS PEAK-TO-PEAK FULL-SCALE RANGE, 3300(8 MM)

View Details
General Electric 3300/16-04-01-00-00-00-00 - DUAL VIBRATION MONITOR
General Electric

General Electric 3300/16-04-01-00-00-00-00 - DUAL VIBRATION MONITOR

View Details
General Electric 3300/16-11-02-01-00-01-00 - DUAL VIBRATION XY/GAP MONITOR
General Electric

General Electric 3300/16-11-02-01-00-01-00 - DUAL VIBRATION XY/GAP MONITOR

View Details
General Electric 3300/16-03-02-00-00-00-00 - DISCONTINUED BY MANUFACTURER, VIBRATION MONITOR, TWO CHANNEL, 0-10 MILS PEAK-TO-PEAK FULL-SCALE RANGE, 3000 PROXIMITOR S
General Electric

General Electric 3300/16-03-02-00-00-00-00 - DISCONTINUED BY MANUFACTURER, VIBRATION MONITOR, TWO CHANNEL, 0-10 MILS PEAK-TO-PEAK FULL-SCALE RANGE, 3000 PROXIMITOR S

View Details
General Electric 3300/16-03-01-01-00-00-00 - DISCONTINUED BY MANUFACTURER, VIBRATION MONITOR, TWO CHANNEL, 0-10 MILS PEAK-TO-PEAK FULL-SCALE RANGE, 3300(8 MM)/3300-X
General Electric

General Electric 3300/16-03-01-01-00-00-00 - DISCONTINUED BY MANUFACTURER, VIBRATION MONITOR, TWO CHANNEL, 0-10 MILS PEAK-TO-PEAK FULL-SCALE RANGE, 3300(8 MM)/3300-X

View Details
General Electric 3300/16-03-01-02-00-00-00 - DISCONTINUED BY MANUFACTURER, DUAL VIBRATION MONITOR, XY/GAP, 0-10 MILS, PP 4-20 MA
General Electric

General Electric 3300/16-03-01-02-00-00-00 - DISCONTINUED BY MANUFACTURER, DUAL VIBRATION MONITOR, XY/GAP, 0-10 MILS, PP 4-20 MA

View Details
General Electric 3300/16-01-01-01-02-01-00 - DUAL VIRBRATION XY/GAP MONITOR
General Electric

General Electric 3300/16-01-01-01-02-01-00 - DUAL VIRBRATION XY/GAP MONITOR

View Details
General Electric 3300/16-02-02-03-01-00-00 - MONITOR DAUL VIBRATION XY/GAP 200MV/MIL 0/5MILS PP
General Electric

General Electric 3300/16-02-02-03-01-00-00 - MONITOR DAUL VIBRATION XY/GAP 200MV/MIL 0/5MILS PP

View Details
General Electric 3300/12-01-20-02 - POWER SUPPLY 95-125VAC 50/60HZ
General Electric

General Electric 3300/12-01-20-02 - POWER SUPPLY 95-125VAC 50/60HZ

View Details
General Electric 3300/15-03-01-01-00-00-00 - DISCONTINUED BY MANUFACTURER, DUAL VIBRATION MONITOR, 0 - -10 VDC, 1 - 5 VDC
General Electric

General Electric 3300/15-03-01-01-00-00-00 - DISCONTINUED BY MANUFACTURER, DUAL VIBRATION MONITOR, 0 - -10 VDC, 1 - 5 VDC

View Details
General Electric 3300/10-02-02-00 - DISCONTINUED BY MANUFACTURER, POWER SUPPLY BOARD, RACK MOUNTING, 3300 SYSTEM
General Electric

General Electric 3300/10-02-02-00 - DISCONTINUED BY MANUFACTURER, POWER SUPPLY BOARD, RACK MOUNTING, 3300 SYSTEM

View Details
General Electric 3300/03-03-02 - SYSTEM MONITOR, 2 WATTS, RS232 PORT, ALARM SETPOINT ADJUSTMENT, KEYPHASOR POWER, 18-24 VDC, DYNAMIC AND SERIAL DATA INTE
General Electric

General Electric 3300/03-03-02 - SYSTEM MONITOR, 2 WATTS, RS232 PORT, ALARM SETPOINT ADJUSTMENT, KEYPHASOR POWER, 18-24 VDC, DYNAMIC AND SERIAL DATA INTE

View Details
General Electric 3300/10-01-02-00 - DISCONTINUED BY MANUFACTURER, POWER SUPPLY AC BOARD, INPUT VOLTAGE OPTION: 95-125 VAC 50/60 HZ, POWER INPUT MODULE OPTIO
General Electric

General Electric 3300/10-01-02-00 - DISCONTINUED BY MANUFACTURER, POWER SUPPLY AC BOARD, INPUT VOLTAGE OPTION: 95-125 VAC 50/60 HZ, POWER INPUT MODULE OPTIO

View Details
General Electric 3300/03-02-00 - SYSTEM MONITOR, 2 W, RS232 PORT, ALARM SETPOINT ADJUSTMENT, KEYPHASOR POWER, 18-24 VDC, SERIAL DATA INTERFACE, NO APPROV
General Electric

General Electric 3300/03-02-00 - SYSTEM MONITOR, 2 W, RS232 PORT, ALARM SETPOINT ADJUSTMENT, KEYPHASOR POWER, 18-24 VDC, SERIAL DATA INTERFACE, NO APPROV

View Details
General Electric 3300/03-01-00 - DISCONTINUED BY MANUFACTURER, SYSTEM MONITOR, 3300/03, 2 WATTS; 4.6 WATTS WITH INTERFACE OPTIONS, RS232 PORT, ALARM SETP
General Electric

General Electric 3300/03-01-00 - DISCONTINUED BY MANUFACTURER, SYSTEM MONITOR, 3300/03, 2 WATTS; 4.6 WATTS WITH INTERFACE OPTIONS, RS232 PORT, ALARM SETP

View Details
General Electric 3300/03-01-03 - DISCONTINUED BY MANUFACTURER, SYSTEM MONITOR, 2 WATTS, RS232 PORT, ALARM SETPOINT ADJUSTMENT, KEYPHASOR POWER, 18-24 VDC
General Electric

General Electric 3300/03-01-03 - DISCONTINUED BY MANUFACTURER, SYSTEM MONITOR, 2 WATTS, RS232 PORT, ALARM SETPOINT ADJUSTMENT, KEYPHASOR POWER, 18-24 VDC

View Details
General Electric 30004-02-12-18-02 - DISCONTINUED BY MANUFACTURER, PROXIMITY PROBE, GAUGE VIBRATION, SWITCH
General Electric

General Electric 30004-02-12-18-02 - DISCONTINUED BY MANUFACTURER, PROXIMITY PROBE, GAUGE VIBRATION, SWITCH

View Details
About This Category

Electrical Controls at Z & F Corporation Ltd

Electrical Controls

These are the field devices that trigger a control action rather than just report a reading — a level switch that starts a pump, a float switch that trips an alarm, a proximity or vibration switch that confirms a machine has actually stopped. Z & F Corporation Ltd supplies genuine control switches and field accessories for plant and process automation, sourced through manufacturer and authorised distributor channels with full documentation on request.

How to Choose a Level or Process Switch

The fluid or material decides the technology before anything else does. Float switches are the simplest and most reliable option for clean liquids in open tanks. Vibrating fork (tuning fork) switches keep working on viscous, sticky or foam-prone liquids where a float would jam or give a false reading. Capacitance switches handle a wider range of media, including some solids and slurries, but need the right probe material for the application. If the process is under pressure or in a hazardous area, that narrows the choice further before contact rating even comes into it.

Once the technology is right, three details make or break the fit: the electrical output (a simple relay contact for a panel indicator lamp is very different from a signal a PLC or SCADA system can read), the housing and probe material (plastic is fine for benign liquids; stainless steel or PTFE-wetted parts are worth the extra cost for anything corrosive or high-purity), and the certification (ATEX/IECEx-rated variants exist for hazardous-area duty, and cost noticeably more than the standard equivalent — only specify it where the area classification actually requires it).

Pro tip — Check the switching action (fail-safe on power loss) before ordering a replacement. A switch that's normally open when energised and one that's normally closed can look identical on a datasheet but behave in opposite ways if power to the loop is lost — worth confirming for anything tied to an alarm or shutdown.

These are the switch types and applications we quote most often, but our sourcing network covers projects worldwide, including the Gulf and South Asia. Send us the application details or an existing part number and request a quote — we'll confirm fit, lead time and documentation.

Need Electrical Controls Products?

Send us your part number, model number or specification and we will source genuine Electrical Controls products with full documentation and fast delivery.

Request a Quote

Frequently Asked Questions

It depends mainly on the fluid: floats suit clean liquids, vibrating fork switches handle viscous or foam-prone media, and capacitance switches cover the widest range including some solids. Send us the application and we'll confirm.