Instrumentation

Product Category

Instrumentation

3532 Products Found

Independent Supplier Notice — Z & F Corporation Ltd is not affiliated with, authorized by, endorsed by, or acting as an official representative of any manufacturer, brand, or trademark owner referenced on this website. All product names, trademarks, brand names, logos, and manufacturer references are the property of their respective owners and are used solely for identification, reference, and compatibility purposes.

Genuine OEM Guaranteed
No grey-market or counterfeit stock
Fast & Reliable Delivery
24-48hr dispatch on in-stock items
Complete Documentation
Certificates & calibration records
Full Catalogue

All Instrumentation Products

Showing 24 of 3532 products

Endress+Hauser FMU860-R1A2B1 - DISCONTINUED BY MANUFACTURER, ULTRASONIC MEASUREMENT, TIME-OF-FLIGHT, PROSONIC, 115 VAC, 15 VA, 50/60 HZ
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMU860-R1A2B1 - DISCONTINUED BY MANUFACTURER, ULTRASONIC MEASUREMENT, TIME-OF-FLIGHT, PROSONIC, 115 VAC, 15 VA, 50/60 HZ

FMU860-R1A2B1

View Details
Endress+Hauser FMU90-N11CA131AA1A - LEVEL TRANSMITTER, 32 POINTS, 90-253VAC, FDU9X/8X, 4-20MA
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMU90-N11CA131AA1A - LEVEL TRANSMITTER, 32 POINTS, 90-253VAC, FDU9X/8X, 4-20MA

FMU90-N11CA131AA1A

View Details
Endress+Hauser FMR56-AAGCAABRXZG - RADAR MEASUREMENT, MICROPILOT FMR56, ACCURACY: 3 MM, PROCESS TEMPERATURE: -40 TO +80 DEGREES C, PROCESS PRESSURE: 3 BAR,
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMR56-AAGCAABRXZG - RADAR MEASUREMENT, MICROPILOT FMR56, ACCURACY: 3 MM, PROCESS TEMPERATURE: -40 TO +80 DEGREES C, PROCESS PRESSURE: 3 BAR,

FMR56-AAGCAABRXZG

View Details
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMU40-ARD1A5 - TRANSMITTER, LEVEL MEASUREMENT, 4-20 MA, 0.7...3 BAR, ULTRASONIC, PVDF, G/NPT 1 1/2INC

FMU40-ARD1A5

View Details
Endress+Hauser FMR230-S4EAVJAA4A - DISCONTINUED BY MANUFACTURER, MICROPILOT, -40 TO 302 F TEMP, 316L FLANGE, 4-20MA, IP65, NEMA 4X, NPT 1/2 INCH CABLE ENTR
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMR230-S4EAVJAA4A - DISCONTINUED BY MANUFACTURER, MICROPILOT, -40 TO 302 F TEMP, 316L FLANGE, 4-20MA, IP65, NEMA 4X, NPT 1/2 INCH CABLE ENTR

FMR230-S4EAVJAA4A

View Details
Endress+Hauser FMR230-V6VA5JAC4B - DISCONTINUED BY MANUFACTURER, LEVEL-RADAR, MICROPILOT M FMR230 SERIES, 10 INCH ANTENNA, FKM VITON ANTENNA SEAL, 10INCH/1
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMR230-V6VA5JAC4B - DISCONTINUED BY MANUFACTURER, LEVEL-RADAR, MICROPILOT M FMR230 SERIES, 10 INCH ANTENNA, FKM VITON ANTENNA SEAL, 10INCH/1

FMR230-V6VA5JAC4B

View Details
Endress+Hauser FMR240-N5V1GNJMA4A - DISCONTINUED BY MANUFACTURER, LEVEL TRANSMITTER, 100 MM ANTENNA, 1/2 NPT THREAD, IP 65, NEMA 4X, STAINLESS STEEL
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMR240-N5V1GNJMA4A - DISCONTINUED BY MANUFACTURER, LEVEL TRANSMITTER, 100 MM ANTENNA, 1/2 NPT THREAD, IP 65, NEMA 4X, STAINLESS STEEL

FMR240-N5V1GNJMA4A

View Details
Endress+Hauser FMP57-AAACCCLDB3AJJ+ - GUIDED RADAR MEASUREMENT, LEVELFLEX FMP57, 11.5-35 VDC, 2 WIRE, 4-20 MA, DISPLAY: SD02 4-LINE - PUSH BUTTONS + DATA BACK
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMP57-AAACCCLDB3AJJ+ - GUIDED RADAR MEASUREMENT, LEVELFLEX FMP57, 11.5-35 VDC, 2 WIRE, 4-20 MA, DISPLAY: SD02 4-LINE - PUSH BUTTONS + DATA BACK

FMP57-AAACCCLDB3AJJ+

View Details
Endress+Hauser FMP53-MHH5/0 - LEVEL, GUIDED RADAR, INTEGRATED DATA MEMORY, RELIABLE MEASURING IN MOVED SURFACE AND FOAM, AMBIENT TEMPERATURE -4 °F TO
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMP53-MHH5/0 - LEVEL, GUIDED RADAR, INTEGRATED DATA MEMORY, RELIABLE MEASURING IN MOVED SURFACE AND FOAM, AMBIENT TEMPERATURE -4 °F TO

FMP53-MHH5/0

View Details
Endress+Hauser FMP57-AAACBDAFB3YYY - LEVEL SENSOR, 2-WIRE, 4-20 MA HART OUTPUT, SD02 4-LINE, PUSH BUTTONS AND DATA BACKUP FUNCTION, GT18 DUAL COMPARTMENT HOU
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMP57-AAACBDAFB3YYY - LEVEL SENSOR, 2-WIRE, 4-20 MA HART OUTPUT, SD02 4-LINE, PUSH BUTTONS AND DATA BACKUP FUNCTION, GT18 DUAL COMPARTMENT HOU

FMP57-AAACBDAFB3YYY

View Details
Endress+Hauser FMI51-R1NRDJA5D1A - CAPACITANCE LEVEL MEASUREMENT, LIQUICAP FMI51, 14 INCH PROBE LENGTH, FEI50H, 4-20 MA HART, NPT 3/4 THREAD, 316L, 25 BAR
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMI51-R1NRDJA5D1A - CAPACITANCE LEVEL MEASUREMENT, LIQUICAP FMI51, 14 INCH PROBE LENGTH, FEI50H, 4-20 MA HART, NPT 3/4 THREAD, 316L, 25 BAR

FMI51-R1NRDJA5D1A

View Details
Endress+Hauser FMP43-AY5TDJB21A4B - DISCONTINUED BY MANUFACTURER, GUIDED LEVEL RADAR, 4-20MAMP, 16-36 VDC, 2 WIRE, TRI-CLAMP, 4-LINE DISPLAY, 1/2 IN NPT THR
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMP43-AY5TDJB21A4B - DISCONTINUED BY MANUFACTURER, GUIDED LEVEL RADAR, 4-20MAMP, 16-36 VDC, 2 WIRE, TRI-CLAMP, 4-LINE DISPLAY, 1/2 IN NPT THR

FMP43-AY5TDJB21A4B

View Details
Endress+Hauser FMP45-AAMASJB24A4A - DISCONTINUED BY MANUFACTURER, LEVEL TRANSMITTER, 1/2 INCH NPT CABLE ENTRY, 2 WIRE, 4-20MA, 4 LINE DISPLAY, F12 ALUMINUM
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMP45-AAMASJB24A4A - DISCONTINUED BY MANUFACTURER, LEVEL TRANSMITTER, 1/2 INCH NPT CABLE ENTRY, 2 WIRE, 4-20MA, 4 LINE DISPLAY, F12 ALUMINUM

FMP45-AAMASJB24A4A

View Details
Endress+Hauser FMP51-H1PD0/0 - DISCONTINUED BY MANUFACTURER, LEVEL CONTROL, 10M MAX MEASURING RANGE OF ROPE PROBE, 45M MAX MEASURING RANGE OF COAX. PRO
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMP51-H1PD0/0 - DISCONTINUED BY MANUFACTURER, LEVEL CONTROL, 10M MAX MEASURING RANGE OF ROPE PROBE, 45M MAX MEASURING RANGE OF COAX. PRO

FMP51-H1PD0/0

View Details
Endress+Hauser FMI21 Series Capacitive Level Sensor Level Sensor, Threaded Mount, Ethylene Propylene Diene Monomer,
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMI21 Series Capacitive Level Sensor Level Sensor, Threaded Mount, Ethylene Propylene Diene Monomer,

FMI21

View Details
Endress+Hauser FMI51-N5HRDJB3D1A - CAPACITANCE LEVEL MEASUREMENT, LIQUICAP, CSA GENERAL PURPOSE, 9 INCH, 316L, 25 BAR, 4-20MA HART
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMI51-N5HRDJB3D1A - CAPACITANCE LEVEL MEASUREMENT, LIQUICAP, CSA GENERAL PURPOSE, 9 INCH, 316L, 25 BAR, 4-20MA HART

FMI51-N5HRDJB3D1A

View Details
Endress+Hauser FMD78-UBC7FB1YYBBU - DISCONTINUED BY MANUFACTURER, DIFFERENTIAL PRESSURE TRANSMITTER WITH TWO DIAPHRAGM SEALS FOR DIFFERENTIAL PRESSURE AND L
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMD78-UBC7FB1YYBBU - DISCONTINUED BY MANUFACTURER, DIFFERENTIAL PRESSURE TRANSMITTER WITH TWO DIAPHRAGM SEALS FOR DIFFERENTIAL PRESSURE AND L

FMD78-UBC7FB1YYBBU

View Details
Endress+Hauser FMB70-QNW9/0 - DISCONTINUED BY MANUFACTURER, METER, SERIES: FMB70, HYDROSTATIC LEVEL MEASUREMENT, NWP 174.9 FTH2O, SPA 40/160 IN H2O
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMB70-QNW9/0 - DISCONTINUED BY MANUFACTURER, METER, SERIES: FMB70, HYDROSTATIC LEVEL MEASUREMENT, NWP 174.9 FTH2O, SPA 40/160 IN H2O

FMB70-QNW9/0

View Details
Endress+Hauser FMB70/CF95/0 - DISCONTINUED BY MANUFACTURER, HYDROSTATIC LEVEL MEASUREMENT, MWP-1MPA, SPAN 10/400KPA
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMB70/CF95/0 - DISCONTINUED BY MANUFACTURER, HYDROSTATIC LEVEL MEASUREMENT, MWP-1MPA, SPAN 10/400KPA

FMB70/CF95/0

View Details
Endress+Hauser FMD78-ABA7F11TK1UA - DISCONTINUED BY MANUFACTURER, PRESSURE TRANSMITTER, 600PSI, 11.5-45VDC
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMD78-ABA7F11TK1UA - DISCONTINUED BY MANUFACTURER, PRESSURE TRANSMITTER, 600PSI, 11.5-45VDC

FMD78-ABA7F11TK1UA

View Details
Endress+Hauser FMB70-ABT1M4257CAA - DISCONTINUED BY MANUFACTURER, HYDROSTATIC LEVEL MEASUREMENT, -400-1600 IN H2O SENSOR NOMINAL RANGE, 0-1600 IN H2O CALIBR
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMB70-ABT1M4257CAA - DISCONTINUED BY MANUFACTURER, HYDROSTATIC LEVEL MEASUREMENT, -400-1600 IN H2O SENSOR NOMINAL RANGE, 0-1600 IN H2O CALIBR

FMB70-ABT1M4257CAA

View Details
Endress+Hauser FMB70-ABT1H4260CAA - DISCONTINUED BY MANUFACTURER, HYDROSTATIC LEVEL MEASUREMENT, 11.5-45 VDC, 4-20 MA, 350 PSI, 1/2 INCH NPT
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMB70-ABT1H4260CAA - DISCONTINUED BY MANUFACTURER, HYDROSTATIC LEVEL MEASUREMENT, 11.5-45 VDC, 4-20 MA, 350 PSI, 1/2 INCH NPT

FMB70-ABT1H4260CAA

View Details
Endress+Hauser FMB70-ABT1H6260CAA - PRESSURE TRANSMITTER, DIGITAL PRESSURE TRANSMITTER, HYDROSTATIC, MODULAR, NON-HAZARDOUS, 4-20 MA HART + LCD, 1.2 BAR / 1
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMB70-ABT1H6260CAA - PRESSURE TRANSMITTER, DIGITAL PRESSURE TRANSMITTER, HYDROSTATIC, MODULAR, NON-HAZARDOUS, 4-20 MA HART + LCD, 1.2 BAR / 1

FMB70-ABT1H6260CAA

View Details
Endress+Hauser FMB70-ABT1HA257CAA - DIGITAL PRESSURE TRANSMITTER, HYDROSTATIC, 4-20MA HART OUTPUT, INSIDE +LCD, MODULAR, TWO-CHAMBER HOUSING
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser FMB70-ABT1HA257CAA - DIGITAL PRESSURE TRANSMITTER, HYDROSTATIC, 4-20MA HART OUTPUT, INSIDE +LCD, MODULAR, TWO-CHAMBER HOUSING

FMB70-ABT1HA257CAA

View Details
About This Category

Instrumentation at Z & F Corporation Ltd

Instrumentation

Instrumentation is how a plant actually knows what's happening inside it — pressure, temperature, flow and level are invisible until an instrument turns them into a number or a signal someone (or something) can act on. Z & F Corporation Ltd supplies genuine measurement instrumentation for process, utility and manufacturing plants, sourced through manufacturer and authorised distributor channels with full documentation on request.

Pressure

Bourdon gauges, diaphragm seals and 4–20mA transmitters for local indication or loop-powered monitoring.

Temperature

Thermocouples, RTDs and temperature transmitters, with sheath materials and connection heads matched to the process.

Flow

Vortex, magnetic and differential-pressure flow meters for liquids, gases and steam across a wide range of line sizes.

Level

Float, ultrasonic and radar level instruments for tanks, vessels and sumps, including point-level switches.

Most instrumentation questions come down to two things: what the process actually needs measured (range, accuracy, and how fast it changes), and how that reading needs to reach the rest of the plant — a local dial is enough for a walk-by check, but a control loop or SCADA system needs an electronic output, usually 4–20mA or a digital protocol such as HART or Modbus. Get the output type right and the rest of the specification usually follows from the process conditions.

Pro tip — If an instrument is replacing an existing one, check the output signal type (analogue vs digital) before the range or accuracy — a perfectly good transmitter is still the wrong part if the control system can't read its output.

These are the instrument families we quote most often, and our sourcing network covers projects worldwide, including the Gulf and South Asia. Send us a tag number, datasheet or existing instrument model and request a quote — we'll confirm fit, lead time and documentation.

Need Instrumentation Products?

Send us your part number, model number or specification and we will source genuine Instrumentation products with full documentation and fast delivery.

Request a Quote

Frequently Asked Questions

Yes — send us the model number or a photo of the nameplate and we'll confirm the exact match or the closest current equivalent if the original has been superseded.