Instrumentation

Product Category

Instrumentation

3532 Products Found

Independent Supplier Notice — Z & F Corporation Ltd is not affiliated with, authorized by, endorsed by, or acting as an official representative of any manufacturer, brand, or trademark owner referenced on this website. All product names, trademarks, brand names, logos, and manufacturer references are the property of their respective owners and are used solely for identification, reference, and compatibility purposes.

Genuine OEM Guaranteed
No grey-market or counterfeit stock
Fast & Reliable Delivery
24-48hr dispatch on in-stock items
Complete Documentation
Certificates & calibration records
Full Catalogue

All Instrumentation Products

Showing 24 of 3532 products

Endress+Hauser 23H50-1F0A1AA0A2AA - DISCONTINUED BY MANUFACTURER, FLOW METER, PROMAG 23, 12-30VDC, 4.20MA
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser 23H50-1F0A1AA0A2AA - DISCONTINUED BY MANUFACTURER, FLOW METER, PROMAG 23, 12-30VDC, 4.20MA

23H50-1F0A1AA0A2AA

View Details
Endress+Hauser 319087-0200B - DISCONTINUED BY MANUFACTURER, CIRCUIT BOARD, FLOWTEC,
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser 319087-0200B - DISCONTINUED BY MANUFACTURER, CIRCUIT BOARD, FLOWTEC,

319087-0200B

View Details
Endress+Hauser 10H80-10J0/139 - DISCONTINUED BY MANUFACTURER, SAFETY PRESSURE VALVE
ON REQUEST
ENDRESS+HAUSER

Endress+Hauser 10H80-10J0/139 - DISCONTINUED BY MANUFACTURER, SAFETY PRESSURE VALVE

10H80-10J0/139

View Details
Parker SCPT Series Pressure Sensor 0 bar 600 bar
ON REQUEST
PARKER HANNIFIN

Parker SCPT Series Pressure Sensor 0 bar 600 bar

View Details
Parker SCPT Series Pressure Sensor 400 bar, Gauge Reading
ON REQUEST
PARKER HANNIFIN

Parker SCPT Series Pressure Sensor 400 bar, Gauge Reading

View Details
Parker SCFTT Series Flow Meter to 60L/min, 1/4 in, G
ON REQUEST
PARKER HANNIFIN

Parker SCFTT Series Flow Meter to 60L/min, 1/4 in, G

View Details
Parker SCFTT Series Flow Meter to 750L/min, 1-7/8 in, UNF
ON REQUEST
PARKER HANNIFIN

Parker SCFTT Series Flow Meter to 750L/min, 1-7/8 in, UNF

View Details
Parker SCFTT Series Turbine Flow Meter Flow Meter for Liquid, 15L/min Min, 600L/min Max
ON REQUEST
PARKER HANNIFIN

Parker SCFTT Series Turbine Flow Meter Flow Meter for Liquid, 15L/min Min, 600L/min Max

View Details
Parker S Series Variable Area Flow Meter for Liquid, 1L/min Min, 25L/min Max
ON REQUEST
PARKER HANNIFIN

Parker S Series Variable Area Flow Meter for Liquid, 1L/min Min, 25L/min Max

View Details
Parker SCFTT Series Flow Meter to 150L/min, 3/4 in, G
ON REQUEST
PARKER HANNIFIN

Parker SCFTT Series Flow Meter to 150L/min, 3/4 in, G

View Details
Parker SCFTT Series Flow Meter to 15L/min, 1/2 in, G
ON REQUEST
PARKER HANNIFIN

Parker SCFTT Series Flow Meter to 15L/min, 1/2 in, G

View Details
Parker SCFTT Series Flow Meter to 300L/min, G
ON REQUEST
PARKER HANNIFIN

Parker SCFTT Series Flow Meter to 300L/min, G

View Details
Parker S Series Flow Meter 0.07L/min to 0.55L/min
ON REQUEST
PARKER HANNIFIN

Parker S Series Flow Meter 0.07L/min to 0.55L/min

View Details
Parker S Series Flow Meter 1.5L/min to 10L/min
ON REQUEST
PARKER HANNIFIN

Parker S Series Flow Meter 1.5L/min to 10L/min

View Details
Parker Liquid Level Indicator M12, M10 FL69321
ON REQUEST
PARKER HANNIFIN

Parker Liquid Level Indicator M12, M10 FL69321

View Details
Parker Liquid Level Indicator FL69221
ON REQUEST
PARKER HANNIFIN

Parker Liquid Level Indicator FL69221

View Details
Parker Liquid Level Indicator M12 FL69113, Metric
ON REQUEST
PARKER HANNIFIN

Parker Liquid Level Indicator M12 FL69113, Metric

View Details
Parker Liquid Level Indicator M12 FL69213, Metric
ON REQUEST
PARKER HANNIFIN

Parker Liquid Level Indicator M12 FL69213, Metric

View Details
Parker Hydraulic Pressure Gauge Isolation Valve, GI1414
ON REQUEST
PARKER HANNIFIN

Parker Hydraulic Pressure Gauge Isolation Valve, GI1414

View Details
Parker GAUGE SET Stainless Steel Feeler Gauge, 4 Blades
ON REQUEST
PARKER HANNIFIN

Parker GAUGE SET Stainless Steel Feeler Gauge, 4 Blades

View Details
Parker G 1/2 FRL, Manual Drain, 5 μm Filtration Size Integrated Pressure Gauge
ON REQUEST
PARKER HANNIFIN

Parker G 1/2 FRL, Manual Drain, 5 μm Filtration Size Integrated Pressure Gauge

View Details
Parker Flow Meter 5L/min to 55L/min
ON REQUEST
PARKER HANNIFIN

Parker Flow Meter 5L/min to 55L/min

View Details
Parker BSPP 1/2 FRL, Automatic Drain, 5 μm Filtration Size Integrated Pressure Gauge
ON REQUEST
PARKER HANNIFIN

Parker BSPP 1/2 FRL, Automatic Drain, 5 μm Filtration Size Integrated Pressure Gauge

View Details
Parker BSPP 1/2 FRL, Manual Drain, 5 μm Filtration Size Integrated Pressure Gauge
ON REQUEST
PARKER HANNIFIN

Parker BSPP 1/2 FRL, Manual Drain, 5 μm Filtration Size Integrated Pressure Gauge

View Details
About This Category

Instrumentation at Z & F Corporation Ltd

Instrumentation

Instrumentation is how a plant actually knows what's happening inside it — pressure, temperature, flow and level are invisible until an instrument turns them into a number or a signal someone (or something) can act on. Z & F Corporation Ltd supplies genuine measurement instrumentation for process, utility and manufacturing plants, sourced through manufacturer and authorised distributor channels with full documentation on request.

Pressure

Bourdon gauges, diaphragm seals and 4–20mA transmitters for local indication or loop-powered monitoring.

Temperature

Thermocouples, RTDs and temperature transmitters, with sheath materials and connection heads matched to the process.

Flow

Vortex, magnetic and differential-pressure flow meters for liquids, gases and steam across a wide range of line sizes.

Level

Float, ultrasonic and radar level instruments for tanks, vessels and sumps, including point-level switches.

Most instrumentation questions come down to two things: what the process actually needs measured (range, accuracy, and how fast it changes), and how that reading needs to reach the rest of the plant — a local dial is enough for a walk-by check, but a control loop or SCADA system needs an electronic output, usually 4–20mA or a digital protocol such as HART or Modbus. Get the output type right and the rest of the specification usually follows from the process conditions.

Pro tip — If an instrument is replacing an existing one, check the output signal type (analogue vs digital) before the range or accuracy — a perfectly good transmitter is still the wrong part if the control system can't read its output.

These are the instrument families we quote most often, and our sourcing network covers projects worldwide, including the Gulf and South Asia. Send us a tag number, datasheet or existing instrument model and request a quote — we'll confirm fit, lead time and documentation.

Need Instrumentation Products?

Send us your part number, model number or specification and we will source genuine Instrumentation products with full documentation and fast delivery.

Request a Quote

Frequently Asked Questions

Yes — send us the model number or a photo of the nameplate and we'll confirm the exact match or the closest current equivalent if the original has been superseded.